Appleton® UNILETS® EYDM200 Dust-Ignitionproof Explosionproof Raintight Conduit Sealing Fitting With Removable Male Nipple, 2 in, For Use With IMC/Threaded Rigid Metallic Conduit, Malleable Iron, Triple Coated
Model:EYDM200
Item:EMS1025979
UPC:781381230179
Pickup or Delivery
Out of stock at Fresno Branch
Shipping
0 available
$109.76EA

Appleton® UNILETS® EYDM200 Dust-Ignitionproof Explosionproof Raintight Conduit Sealing Fitting With Removable Male Nipple, 2 in, For Use With IMC/Threaded Rigid Metallic Conduit, Malleable Iron, Triple Coated
Model:EYDM200
Item:EMS1025979
UPC:781381230179
Pickup or Delivery
Out of stock at Fresno Branch
Shipping
0 available
$109.76EA
Product Information
Brand : Appleton®
Alternate Part Number : 8328184
Appleton® UNILETS® Conduit Sealing Fitting, Dust-Ignitionproof Explosionproof Raintight, Series: EYDM, 2 in, For Use With: IMC/Threaded Rigid Metallic Conduit, Malleable Iron, Triple Coated, 6.13 in L x 2.88 in W
- ColorSilverCountry of OriginMXDimensions6.13 in L x 2.88 in WFinishTriple CoatedManufacturer NameEmerson ElectricMaterialMalleable IronSeriesEYDMSize2 inSuitable For Use WithIMC/Threaded Rigid Metallic ConduitTypeDust-Ignitionproof Explosionproof Raintight
- For prevent passage of gases, vapors or flames from one portion of conduit system to another
- Smooth, rounded integral bushing in each hub to protect conductor insulation
- Accurately tapped, tapered NPT threads for tight, rigid joints and ground continuity
- Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub
- Close radius type for sealing vertical conduit runs
- Restrict any explosion to the sealed off enclosure
- Required in Class I, Division 1 and 2 locations within 18 in of enclosures containing apparatus that may cause arcs, sparks or high temperatures
- Required in Class I, Division 1 and 2 locations where 2 in or larger conduit enters enclosure, fitting housing terminals, splices or taps
- Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location
- Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 in or less conduit, seal must be located within 18 in of either enclosure
- Required where cables which exceed rate of gas or vapor transmission permitted for seals are used in Class I, Division 2 locations
- Tapered MNPT X tapered FNPT connection
- 25% fill vertical conduit drain sealing fittings
- Access cover has drain valve for automatic draining of water accumulation above the seal
- Chromate/epoxy powder coated/zinc electroplated finish
- UL 886|UL 1203|UL File No. E10444|CSA C22.2 No. 30|CSA 065181, Class I, Groups B, C, D, Class II, Groups E, F, G, Class III