Appleton® UNILETS® EYS6 Dust-Ignitionproof Explosionproof Raintight Conduit Sealing Fitting, 2 in, For Use With IMC/Threaded Rigid Metallic Conduit, Grayloy-Iron, Triple Coated
Model:EYS6
Item:EMS1025993
UPC:781381621069
Pickup or Delivery
11 In Stock at Fresno Branch
Shipping
0 available
$102.40EA

Appleton® UNILETS® EYS6 Dust-Ignitionproof Explosionproof Raintight Conduit Sealing Fitting, 2 in, For Use With IMC/Threaded Rigid Metallic Conduit, Grayloy-Iron, Triple Coated
Model:EYS6
Item:EMS1025993
UPC:781381621069
Pickup or Delivery
11 In Stock at Fresno Branch
Shipping
0 available
$102.40EA
Product Information
Brand : Appleton®
Alternate Part Number : 8192186
These Appleton® sealing fittings minimize the passage of gases and vapors and prevent the passage of flames from one portion of a conduit system to another. They prevent pressure piling within the conduit system and contain any explosion that occurs. These models in the EYS series provide a close turning radius and can be used for sealing vertical or horizontal conduit runs.
- ColorGrayCountry of OriginMXDimensions6-1/4 in L x 3 in WFinishTriple CoatedManufacturer NameEmerson ElectricMaterialGrayloy-IronSeriesEYSSize2 inSuitable For Use WithIMC/Threaded Rigid Metallic ConduitTypeDust-Ignitionproof Explosionproof Raintight
- For prevent passage of gases, vapors or flames from one portion of conduit system to another
- Smooth, rounded integral bushing in each hub to protect conductor insulation
- Accurately tapped, tapered NPT threads for tight, rigid joints and ground continuity
- Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub
- Large opening for damming and filling
- Restrict any explosion to the sealed off enclosure
- Required in Class I, Division 1 and 2 locations within 18 in of enclosures containing apparatus that may cause arcs, sparks or high temperatures
- Required in Class I, Division 1 and 2 locations where 2 in or larger conduit enters enclosure, fitting housing terminals, splices or taps
- Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location
- Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 in or less conduit, seal must be located within 18 in of either enclosure
- Required where cables which exceed rate of gas or vapor transmission permitted for seals are used in Class I, Division 2 locations
- Tapered FNPT connection
- 25% fill vertical and horizontal conduit sealing fittings for close turning radius
- Chromate/epoxy powder coated/zinc electroplated finish
- UL 886|UL 1203 File No. E10444|CSA C22.2 No. 30|CSA 065181