GE CR463L30AJA10A0 Electrically/Mechanically Held Lighting Contactor, 110/120 VAC V Coil, 30 A, 3NO Contact, 3 Poles
Model:CR463L30AJA10A0
Item:EMS1023076
UPC:783166620793
Pickup or Delivery
Out of stock at Fresno Branch
Shipping
0 available
$222.00EA

GE CR463L30AJA10A0 Electrically/Mechanically Held Lighting Contactor, 110/120 VAC V Coil, 30 A, 3NO Contact, 3 Poles
Model:CR463L30AJA10A0
Item:EMS1023076
UPC:783166620793
Pickup or Delivery
Out of stock at Fresno Branch
Shipping
0 available
$222.00EA
Product Information
Brand : GE
Alternate Part Number : 7632425
CR463L electrically held contactor 30 A (2 to 12-pole). Standard assembled form. Contact position indication when button protrude, contact is closed. Power pole are available as single or double pole, creating 74 different circuit combination. Convenient side access field power wiring. Contact configuration indicator. Standard base for all pole configuration. Robust pole terminal accept up to two 8 AWG wire. Manual operator. Fast, sure 3-point mounting. Enclosed contact resist contaminant for greater reliability. Combination slotted/#2 Phillips screw. Common, easily installed power pole change from NO to NC (or vice versa) simply by unlatching and rotating 180 deg. Power pole rated for the range of task, 30 A rated contact, 15 A motor rated, A600 Pilot duty rated. Easy to read rating label. Auxiliary contact, rated A600 are suitable for use on low level circuit down to 12 V, 5 mA. Plug-in auxiliary contact are NO when installed on the left side of the base, NC on the right. Finger and back of hand safe power terminal. Quick-view coil voltage. Easy change coil. Low magnetic noise results in quiet operation.
Additional Resources
- Coil Voltage110/120 VACContact Configuration3NOContact Rating30 AContact TypeAuxiliaryEnclosure TypeNEMA 1Frequency Rating50/60 HzManufacturer NameABBMaximum Load Current30 AMounting TypeSurfaceNumber of Poles3SeriesCR463LTerminal TypeFinger SafeTypeElectrically/Mechanically Held
- For fluorescent or HID switch ballast, tungsten and general use load and carry motor load, resistive, pilot duty rating, electrical distribution and control application
- Poles may be reconfigured by the user into alternative combination of NO and NC contact
- 3 wire control is typically used when control is desired from multiple location
- Contactor is operated from a momentary pilot device and require an auxiliary contact to be used as a holding interlock
- 2 wire control is used for single location control with power continuously supplied to the coil for contactor operation
- Contact position indication when button protrude, contact is closed
- Convenient side access field power wiring
- Contact configuration indicator
- Standard base for all pole configuration
- Robust pole terminal accept up to two 8 AWG wire
- Manual operator
- Fast, sure 3-point mounting, enclosed contacts resist contaminant for greater reliability
- Combination slotted/#2 Phillips® screw
- Common, easily installed power pole change from NO to NC (or vice versa) simply by unlatching and rotating 180 deg
- Power poles rated for the range of task
- 15 A motor rated
- A600 pilot duty rated easy to read rating label
- Auxiliary contact, rated A600 are suitable for use on low level circuit down to 12 VAC, 5 mA
- Plug-in auxiliary contact are no when installed on the left side of the base, NC on the right
- Finger and back of hand safe power terminal
- CE Marked|cUL Listed|UL 508