Brand : ABB
Alternate Part Number : 1SAM451000R1016
MS165 is a compact and powerful range for motor protection up to 45 kW (400 V) / 80 A in width of 55 mm. They offer a reliable protection for motors in the event of overload or phase failure. The devices have trip class 10. This type has also a clear and reliable indication of fault in a separate window in the event of short-circuit tripping. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter (also known as motor protection circuit breaker or manual motor protector) is suitable for three- and single phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory. These are suitable throughout the MS116/MS132/MS165 range.
- ActionON/OFF/TripAmperage Rating54 AConnection TypeScrewControl TypeRotary HandleCountry of OriginCNDimensions55 mm W x 122.1 mm D x 142.65 mm HEnclosure TypeIP20, IP20/IP109Frequency Rating50/60 HzFull Load Current52 ALoad Capacity30 kAManufacturer NameABBMotor Power50 hpNumber of Poles3Operating Cycles25000/50000 CyclesOperating Temperature-25 to 60 deg CPhase3SeriesMS165Setting40 to 54 AVoltage Rating600 VACWattage22 kW
- For use to provide a disconnect function for safely isolation of the installation and the supply and can be used for the manual switching of loads
- Overload protection - trip class 10
- Phase loss sensitivity
- Disconnect function
- Adjustable and sealable current setting for overload protection
- Trip-free mechanism
- Status indication for short-circuit trip
- 48.3 A at 200 VAC 3 ph, 46.2 A at 208 VAC 3 ph, 54 A at 220 to 240 VAC 3 ph, 52 A at 440 to 480 VAC 3 ph, 52 A at 550 to 600 VAC 3 ph
- 15 hp at 200 VAC 3 ph, 15 hp at 208 VAC 3 ph, 20 hp at 220 to 240 VAC 3 ph, 40 hp at 440 to 480 VAC 3 ph, 50 hp 550 to 600 VAC 3 ph
- BAA Compliant|CSA 22.2 No. 14|IEC/EN 60947-1|IEC/EN 60947-2|IEC/EN 60947-4-1|UL 60947-4-1|EU Directive 2011/65/EU|ABS Certified|BV Certified|CB Certified|CCC Certified|cUL Listed|CE Certified|DNV GL Certified|EAC Certified|KC Certified|LR Certified|RMRS Certified|cUL E137861|UL E137861|cUL E345003|UL 345003