ABB AF30-30-11-13 Non-Reversing Line Contactor, 100 to 250 V AC/DC V Coil, 50 A, 3NO Contact, 3 Poles
Model:AF30-30-11-13
Item:EMS1017909
UPC:888614244276
Pickup or Delivery
Only 2 left in stock at Fresno Branch order soon
Shipping
0 available
$169.77/Each

ABB AF30-30-11-13 Non-Reversing Line Contactor, 100 to 250 V AC/DC V Coil, 50 A, 3NO Contact, 3 Poles
Model:AF30-30-11-13
Item:EMS1017909
UPC:888614244276
Pickup or Delivery
Only 2 left in stock at Fresno Branch order soon
Shipping
0 available
$169.77/Each
Product Information
Brand : ABB
Alternate Part Number : 1SBL277001R1311
AF30 contactors are used for controlling power circuits up to 690 VAC and 220 VDC. They are mainly used for controlling 3 ph motors, non-inductive or slightly inductive loads. AF... contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24 to 500 V 50/60 Hz or 20 to 500 VDC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 2-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles with a non-removable front-mounted 1 NO + 1 NC auxiliary contact block, side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 including the "Mechanically" symbol on the contactor side. NC mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC operated - Accessories: a wide range of accessories is available. Note: 2-stack contactors available in some countries: please consult your ABB representative.
Additional Resources
- Coil Power Rating10 hp, 20 hp, 25 hp, 2 hp, 5 hpCoil Voltage100 to 250 V AC/DCContact Configuration3NOContact Rating50 A at 690 VCountry of OriginFRDimensions45 mm W x 111.5 mm D x 86 mm HEnclosure TypeIP20Manufacturer NameABBMaximum Load Current50 ANumber of Auxiliary Contacts1NO-1NCNumber of Poles3Operating Temperature-60 to 80 deg CSeriesAF SeriesSizeAF30Terminal TypeScrewTypeNon-ReversingWattage9/15/18.5 kW
- For controlling 3 ph motors, non-inductive or slightly inductive loads
- Control circuit - AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100 to 250 VAC and VDC), only 4 control voltage ranges covering 24 to 500 V 50/60 Hz and 20 to 500 VDC
- Can manage large control voltage variations
- Reduced panel energy consumption
- Very distinct closing and opening
- Built-in surge suppression
- Add-on auxiliary contact blocks for front or side mounting and a wide range of accessories
- 50 A at 690 V, 42 A at 690 V, 37 A at 690 V rated operational current AC-1
- 33 A at 220/230/240 V, 32 A at 380/400 V, 32 A at 415 V, 32 A at 440 V, 28 A at 500 V, 21 A at 690 V rated operational current AC-3
- 10 hp at 220 to 240 VAC 3 ph, 20 hp at 440 to 480 VAC 3 ph, 25 hp at 550 to 600 VAC 3 ph, 2 hp at 120 VAC 1 ph, 10 hp at 200 to 208 VAC 3 ph, 5 hp at 240 VAC 1 ph
- 9 kW at 220/230/240 V, 15 kW at 380/400 V, 15 kW at 415 V, 18.5 kW at 440 V, 18.5 kW at 500 V, 18.5 kW at 690 V, 15 kW at 400 V
- BAA Compliant|BV Certified|CB Certified|CCC Certified|DNV GL Certified|LR Certified|RMRS Certified