ABB MS165-42 MS165 Manual Motor Starter, ON/OFF/Trip Action, 3 Poles, IP20 Enclosure
Model:MS165-42
Item:EMS1034308
UPC:888614384217
Pickup or Delivery
Out of stock at Fresno Branch
Shipping
0 available
$639.27/Each

ABB MS165-42 MS165 Manual Motor Starter, ON/OFF/Trip Action, 3 Poles, IP20 Enclosure
Model:MS165-42
Item:EMS1034308
UPC:888614384217
Pickup or Delivery
Out of stock at Fresno Branch
Shipping
0 available
$639.27/Each
Product Information
Brand : ABB
Alternate Part Number : 1SAM451000R1015, 13658837, 1SAM451000R1015
MS165 is a compact and powerful range for motor protection up to 45 kW (400 V)/80 A in width of 55 mm. They offer a reliable protection for motors in the event of overload or phase failure. The devices have trip class 10. This type has also a clear and reliable indication of fault in a separate window in the event of short circuit tripping. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter (also known as motor protection circuit breaker or manual motor protector) is suitable for three and single phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory. These are suitable throughout the MS116/MS132/MS165 range.
- ActionON/OFF/TripAmperage Rating42 AConnection TypeScrewControl TypeRotary HandleCountry of OriginCNDimensions55 mm W x 122.1 mm D x 142.65 mm HEnclosure TypeIP20Frequency Rating50/60 HzFull Load Current42 ALoad Capacity50 kAManufacturer NameABBMotor Power40 hpNumber of Poles3Operating Cycles25000/50000Operating Temperature-25 to 60 deg COverload RelayClass 10 ThermalPhase3SeriesMS165Setting30 to 42 AVoltage Rating600 V ACWattage22 kW
- For use to provide a disconnect function for safely isolation of the installation and the supply and can be used for the manual switching of loads
- Adjustable and sealable current setting for overload protection
- Fuseless starter combinations are setup together with contactors
- Disconnect function
- Status indication for short-circuit trip
- Fuseless protection with a manual motor starter saves costs, space and ensures a quick reaction under short circuit condition, by switching off the motor within milliseconds
- Trip-free mechanism
- Overload protection - trip class 10
- Electrical 25000 cycle, mechanical 50000 cycle
- 32.2 A at 200 VAC 3 ph, 30.8 A at 208 VAC 3 ph, 42 A at 220 to 240 VAC 3 ph, 40 A at 440 to 480 VAC 3 ph, 41 A at 550 to 600 VAC 3 ph
- Phase loss sensitivity
- Manual motor starters (also known as motor protection circuit breakers or manual motor protectors) are electromechanical protection devices for the main circuit mainly used to switch motors manually ON/OFF and protect them fuseless against short circuits, overloads and phase failures
- RoHs, CSA, cUL, CE, GOST