ABB XT1NU3015AAA000XXX Tmax XT Low Voltage Molded Case Circuit Breaker, 600Y/347/690 V AC, 15 A, 18 kA Interrupt, 3 Poles, Thermal Magnetic Trip
Model:XT1NU3015AAA000XXX
Item:EMS1047674
UPC:888614429215
Pickup or Delivery
Only 1 left in stock at Fresno Branch order soon
Shipping
0 available
$415.75/Each

ABB XT1NU3015AAA000XXX Tmax XT Low Voltage Molded Case Circuit Breaker, 600Y/347/690 V AC, 15 A, 18 kA Interrupt, 3 Poles, Thermal Magnetic Trip
Model:XT1NU3015AAA000XXX
Item:EMS1047674
UPC:888614429215
Pickup or Delivery
Only 1 left in stock at Fresno Branch order soon
Shipping
0 available
$415.75/Each
Product Information
Brand : ABB
Alternate Part Number : 18260298, 13941891
Tmax XT molded case circuit breakers guarantee an extremely high performance level while being progressively smaller in size, simple to install and able to provide increasingly better safety.
- Number of Poles3Amperage Rating15 AVoltage Rating600Y/347/690 V ACTrip Range15 to 500 ATypeLow VoltageConnection TypeFC Cu Line/Load SideCountry of OriginITDimensions5.12 in H x 3 in W x 2.75 in DFrameXT1 125AFrequency Rating50/60 HzInsulation TypeDouble InsulatedInterrupt Rating18 kAManufacturer NameABBSeriesTmax XTTemperature Rating-13 to 158 deg FTrip TypeThermal Magnetic
- For all distribution levels from the main low voltage switchboard to the sub-switchboards in the installation
- Specific electronic trip units for energy metering, motor protection and generator protection in addition to a Modbus communication module for integration in a supervision system
- Wide range of keylocks and padlocking options, plug-in and withdrawable versions to speed up maintenance operations and improved diagnostic to have ready to use information about breakers status
- A dedicated range of accessories and a renewed solution for electronic trip units to adapt Tmax XT to different applications scenarios installation flexibility
- XTraordinary limiting characteristics allow savings in copper and footprint in switchboard, high selectivity values and very compact motor protection solutions high breaking capacity
- FC copper terminals for copper cables on line and load side termination (top/bottom)
- 18 kA normal breaking capacity
- Frame XT1 to 125A, 600Y/347 V (UL)/160 A, 690 V (IEC) thermal magnetic protection
- Feature high specific let-through current peak and energy limiting characteristics that allow the circuits and equipment on the load side to be sized in optimum way
- UL Listed|CSA Certified|IEC Dual Rated|UL Listed|CSA Certified|IEC Certified